Home
Low Voltage Cables

NAY2Y

The NAY2Y cable is an especially robust low-voltage cable with an aluminium conductor and an HDPE sheath, specifically developed for installations with high mechanical stress. It stands out for its durability in demanding environments – whether in industrial facilities, transformer stations, or local networks.

NAY2Y
NAY2Y

Request a Quote

Get technical specifications and pricing for your project.

By submitting you agree to our privacy policy

For demanding installation conditions

The NAY2Y meets the requirements of TP PRAKAB 12/03 based on VDE 0276-603 and is suitable for fixed installation indoors, in cable ducts, underground, in water, and outdoors. It is ideal for applications in power plants, industrial and switching stations, as well as local supply networks – wherever mechanical stress during installation or operation plays a significant role.

Construction and material components

The conductor is made of aluminium, available as solid round (RE), stranded round (RM), or sector-shaped (SE/SM). The PVC-insulated cores are stranded together and protected by a common EPDM sheath. The outer sheath of HDPE (black, UV-resistant) makes the cable particularly resistant to pressure, abrasion, and moisture – perfect for long-term installations under challenging conditions.

Typical applications

NAY2Y cables are the first choice for cabling projects with high loads, such as in industrial network construction or outdoor power distribution. They offer a robust, durable, and cost-efficient solution for stable power supply in a wide variety of environments.

Technical Specifications

General Data

Bending radius (mm)
15/12xD mm
CPR class
Fca
Maximal operating conductor temperature (°C)
70 °C
Maximal short-circuit temperature (°C)
300 mm2: +140 °C
Minimal storage temperature (°C)
-35 °C
Minimal temperature for laying (°C)
-5 °C
Operating temperature range (°C)
-35-+70 °C
Rated voltage (kV)
0.6/1 kV
Self-extinguishing of single cable
no
Test voltage (kV)
4 kV

0.6/1 kV

Voltage
0.6/1 kV
Test voltage
4 kV
Operating temperature range
-35-+70 °C
Conductor temperature (max.)
70 °C
Short-circuit temperature (max.)
300 mm2: +140 °C
Minimum laying temperature
-5 °C
Minimum storage temperature
-35 °C
CPR class
Fca
Flame retardant
no
Config.Cond.ShapeRI [Ohm/km]Wi [mm]Wm [mm]Rbv [mm]Ø [mm]G [kg/km]
1x16AlRE1.9111.812xD11122
1x25AlRE1.21.21.812xD12171
1x35AlRE0.8681.21.812xD13209
1x50AlRMV0.6411.41.812xD15277
1x70AlRMV0.4431.41.812xD17356
1x95AlRMV0.321.61.812xD19464
1x120AlRMV0.2531.61.812xD20549
1x150AlRMV0.2061.81.812xD22670
1x185AlRMV0.16421.812xD25821
1x240AlRMV0.1252.21.812xD271035
1x300AlRMV0.12.41.912xD301273
1x400AlRMV0.07782.6212xD341598
1x500AlRMV0.06052.82.112xD372001
3x10AlRE3.0811.812xD18398
3x16AlRE1.9111.812xD20523
3x25AlRE1.21.21.812xD24735
3x35AlRE0.8681.21.812xD26903
3x50AlSE0.6411.41.812xD27955
3x70AlSE0.4431.4212xD311263
3x95AlSE0.321.62.112xD341625
3x120AlSE0.2531.62.212xD371911
3x150AlSE0.2061.82.312xD412329
3x185AlSE0.16422.512xD452821
3x240AlSE0.1252.22.712xD503573
3x35+16AlRE0.8681.2/1.01.812xD27981
3x50+25AlSM/RMV0.6411.4/1.21.912xD301222
3x70+35AlSM/RMV0.4431.4/1.2212xD341582
3x95+50AlSM0.321.6/1.42.212xD392004
3x120+70AlSM0.2531.6/1.42.312xD422429
3x150+70AlSM0.2061.8/1.42.412xD472854
3x185+95AlSM0.1642.0/1.62.612xD513492
3x240+120AlSM0.1252.2/1.62.812xD584437
4x16AlRE1.9111.812xD22611
4x16AlRMV1.9111.812xD23649
4x25AlRE1.21.21.812xD26873
4x25AlRMV1.21.21.812xD26906
4x35AlRE0.8681.21.812xD281071
4x50AlSE0.6411.41.912xD301238
4x50AlSM0.6411.41.912xD311324
4x70AlSE0.4431.42.112xD331591
4x95AlSE0.321.62.212xD372068
4x120AlSE0.2531.62.412xD412518
4x150AlSE0.2061.82.512xD453013
4x150AlSM0.2061.82.512xD483183
4x185AlSE0.16422.712xD503732
4x185AlSM0.16422.712xD533928
4x240AlSE0.1252.22.912xD564648
4x240AlSM0.1252.22.912xD594929
5x16AlRE1.9111.812xD24721
5x25AlRE1.21.21.812xD281059
5x35AlRE0.8681.21.912xD311320
5x50AlSM0.6411.4212xD351661
5x70AlSM0.4431.42.212xD402137
5x95AlSM0.321.62.412xD452816
5x120AlSM0.2531.62.512xD493342