Home
Low Voltage Cables

N2X2Y

The N2X2Y cable is an XLPE-insulated low-voltage cable with an HDPE sheath, developed for fixed installations under demanding conditions. It stands out for its high thermal endurance and is ideally suited for use in power distribution systems with increased safety requirements.

N2X2Y
N2X2Y

Request a Quote

Get technical specifications and pricing for your project.

By submitting you agree to our privacy policy

For demanding operating conditions

The N2X2Y complies with HD 603 S1 Part 5G and HD 627 S1 Part 4H (equivalent to DIN VDE 0276-603 and -627) and is designed for an operating frequency of 50 Hz. It is suitable for fixed installation indoors, underground, outdoors, and in industrial environments with high temperature and load requirements. The maximum operating temperature is +90 °C, and +250 °C is permissible under short-circuit conditions.

Construction and technical features

The cable structure consists of copper conductors with XLPE insulation (cross-linked polyethylene). The cores are stranded and surrounded by a robust black HDPE sheath. The integrated concentric conductor made of copper wires is grounded at both ends and provides effective protection against potential differences and contact voltages.

Fields of application

N2X2Y is ideal for installations in local networks, substations, and industrial plants as well as in power distribution systems, where high thermal endurance and mechanical strength are required. It provides a durable solution for demanding operating conditions – reliable and safe.

Technical Specifications

General Data

Bending radius (mm)
15/12xD mm
CPR class
Fca
Maximal operating conductor temperature (°C)
90 °C
Maximal short-circuit temperature (°C)
250 °C
Minimal storage temperature (°C)
-35 °C
Minimal temperature for laying (°C)
-20 °C
Operating temperature range (°C)
-35-+90 °C
Rated voltage (kV)
0.6/1 kV
Self-extinguishing of single cable
no
Test voltage (kV)
4 kV

0.6/1 kV

Voltage
0.6/1 kV
Test voltage
4 kV
Operating temperature range
-35-+90 °C
Conductor temperature (max.)
90 °C
Short-circuit temperature (max.)
250 °C
Minimum laying temperature
-20 °C
Minimum storage temperature
-35 °C
CPR class
Fca
Flame retardant
no
Config.Cond.ShapeRI [Ohm/km]Wi [mm]Wm [mm]Rbv [mm]Ø [mm]G [kg/km]
1x10CuRE1.830.71.812xD9141
1x16CuRE1.150.71.812xD10200
1x25CuRMV0.7270.91.812xD12301
1x35CuRMV0.5240.91.812xD13397
1x50CuRMV0.38711.812xD14520
1x70CuRMV0.2681.11.812xD16725
1x95CuRMV0.1931.11.812xD18972
1x120CuRMV0.1531.21.812xD201207
1x150CuRMV0.1241.41.812xD221488
1x240CuRMV0.09911.71.812xD262388
1x300CuRMV0.06011.81.812xD292964
1x400CuRMV0.04721.912xD323772
1x500CuRMV0.03662.2212xD364808
3x10CuRE1.830.71.812xD17529
3x16CuRE1.150.71.812xD19741
3x25CuRMV0.7270.91.812xD231122
3x35CuRMV0.5240.91.812xD261473
3x50CuSM0.38711.812xD261729
3x70CuSM0.2681.11.912xD302414
3x95CuSM0.1931.1212xD333210
3x120CuSM0.1531.22.112xD373962
3x150CuSM0.1241.42.312xD414906
3x185CuSM0.09911.62.412xD456047
3x240CuSM0.07541.72.612xD517833
3x35+16CuRMV/RE0.5240.9/0.71.812xD261652
3x50+25CuSM/RMV0.3871.0/0.91.812xD292075
3x70+35CuSM0.2681.1/0.91.912xD322828
3x95+50CuSM0.1931.1/1.02.112xD373757
3x120+70CuSM0.1531.2/1.12.212xD404707
3x150+70CuSM0.1241.4/1.12.312xD455675
3x185+95CuSM0.09911.6/1.12.512xD497071
3x240+120CuSM0.07541.7/1.22.712xD569138
4x10CuRE1.830.71.812xD18642
4x16CuRE1.150.71.812xD21910
4x25CuRMV0.7270.91.812xD251391
4x35CuRMV0.5240.91.812xD281834
4x50CuSM0.38711.912xD292255
4x70CuSM0.2681.1212xD333158
4x95CuSM0.1931.12.112xD374200
4x120CuSM0.1531.22.312xD415259
4x150CuSM0.1241.42.412xD466439
4x185CuSM0.09911.62.612xD517967
4x240CuSM0.07541.72.812xD5710324
5x10CuRE1.830.71.812xD20767
5x16CuRE1.150.71.812xD221100
5x25CuRMV0.7270.91.812xD271676
5x35CuRMV0.5240.91.812xD312266
5x50CuSM0.3871212xD332877
5x70CuSM0.2681.12.112xD383979
5x95CuSM0.1931.12.312xD425342
5x120CuSM0.1531.22.412xD476625