The N2XSY cable is a high-performance medium-voltage cable with a copper conductor, XLPE insulation, and a PVC sheath. It offers excellent electrical characteristics and can be installed safely and efficiently, even in complex routing situations.

N2XSY
N2XSY

Request a Quote

Get technical specifications and pricing for your project.

By submitting you agree to our privacy policy

For powerful medium-voltage applications

The N2XSY meets the standards DIN VDE 0276-620, HD 620 S2 and IEC 60502. It is designed for installation indoors, in cable ducts, in water, underground, or outdoors (when protected). Whether in industrial plants, power stations, or substations – this cable ensures safe and low-loss power transmission in medium-voltage networks.

Construction and technical features

The cable consists of a bare, multi-stranded copper conductor (Class 2), surrounded by XLPE insulation with a tightly bonded outer conductive layer. A conductive tape, a copper wire screen with counter helix, additional tape, and a red PVC sheath (Type DMV6) complete the construction. The extruded combination of insulation and conductive layer ensures partial discharge-free operation and high reliability.

Properties and application benefits

The N2XSY cable is suitable for underground installation, flame-retardant according to DIN VDE 0482-332-1-2, and free from silicone and cadmium-containing substances. With a +90 °C operating temperature and +250 °C short-circuit resistance, it is ideal for networks with high thermal loads. Excellent installation properties also allow for easy handling, even in complex routing scenarios.

Technical Specifications

General Data

CPR class
Eca
Maximal operating conductor temperature (°C)
+90 °C
Maximal short-circuit temperature (°C)
+250 °C
Minimal storage temperature (°C)
-25 °C
Minimal temperature for laying (°C)
-5 °C
Operating temperature range (°C)
-35-+90 °C
Shape of conductor
RM

6/10 kV

Voltage
6/10 kV
Test voltage
21 kV
Operating temperature range
-35-+90 °C
Conductor temperature (max.)
+90 °C
Short-circuit temperature (max.)
+250 °C
Minimum laying temperature
-5 °C
Minimum storage temperature
-25 °C
CPR class
Eca
Flame retardant
EN 60 332-1-2 / EN 60 332-1-3 / EN 60 332-1-4 / EN 60 332-1-5 / EN 60 332-1-6 / EN 60 332-1-7 / EN 60 332-1-8 / EN 60 332-1-9 / EN 60 332-1-10 / EN 60 332-1-11 / EN 60 332-1-12
Config.Cond.ShapeCap [uF/km]DI [mm]RI [Ohm/km]Wi [mm]Ibl [A]Ibe [A]Ik [kA]Wm [mm]Rbv [mm]Ø [mm]G [kg/km]
1x35/16CuRM0.2215.30.5243.419718752.136024904
1x50/16CuRM0.2416.30.3873.42382207.12.1390261039
1x70/16CuRM0.2817.90.2683.4294268102.1405271271
1x95/16CuRM0.319.40.1933.435832013.62.1435291530
1x120/16CuRM0.3420.90.1533.441336317.12.1450301809
1x150/25CuRM0.3622.30.1243.446840521.42.1480322158
1x185/25CuRM0.423.90.0993.453545626.42.1495332524
1x240/25CuRM0.4426.40.0753.463152634.32.1540363117
1x300/25CuRM0.4928.80.063.472259142.92.1570383786
1x400/35CuRM0.5431.40.0473.482766257.22.1615414750
1x500/35CuRM0.6134.60.0373.494974471.42.1660445786

12/20 kV

Voltage
12/20 kV
Test voltage
42 kV
Operating temperature range
-35-+90 °C
Conductor temperature (max.)
+90 °C
Short-circuit temperature (max.)
+250 °C
Minimum laying temperature
-5 °C
Minimum storage temperature
-25 °C
CPR class
Eca
Flame retardant
EN 60 332-1-2
Config.Cond.ShapeCap [uF/km]DI [mm]RI [Ohm/km]Wi [mm]Ibl [A]Ibe [A]Ik [kA]Wm [mm]Rbv [mm]Ø [mm]G [kg/km]
1x35/16CuRM0.1619.50.5245.520018952.1435291069
1x50/16CuRM0.1720.50.3875.52392227.12.1450301203
1x70/16CuRM0.1922.10.2685.5297271102.1465311447
1x95/16CuRM0.2123.60.1935.536132313.62.1495331718
1x120/16CuRM0.2325.10.1535.541636717.12.1510342007
1x150/25CuRM0.2526.50.1245.547040921.42.1540362364
1x185/25CuRM0.2728.10.0995.553846126.42.1555372744
1x240/25CuRM0.330.60.0755.563453234.32.1600403352
1x300/25CuRM0.35330.065.572459942.92.1630424032
1x400/35CuRM0.3635.60.0475.582967157.22.1675454988
1x500/35CuRM0.4338.80.0375.595375471.42.1720486080

18/30 kV

Voltage
18/30 kV
Test voltage
63 kV
Operating temperature range
-35-+90 °C
Conductor temperature (max.)
+90 °C
Short-circuit temperature (max.)
+250 °C
Minimum laying temperature
-5 °C
Minimum storage temperature
-25 °C
CPR class
Eca
Flame retardant
EN 60 332-1-2
Config.Cond.ShapeCap [uF/km]DI [mm]RI [Ohm/km]Wi [mm]Ibl [A]Ibe [A]Ik [kA]Wm [mm]Rbv [mm]Ø [mm]G [kg/km]
1x50/16CuRM0.1325.50.38782412257.12.1525351439
1x70/16CuRM0.1527.10.2688299274102.1540361697
1x95/16CuRM0.1628.60.193836332713.62.1570381979
1x120/16CuRM0.1730.10.153841837117.12.1585392279
1x150/25CuRM0.1931.50.124847241421.42.1615412648
1x185/25CuRM0.233.10.099853946626.42.1630423036
1x240/25CuRM0.2235.60.075863553934.32.1675453661
1x300/25CuRM0.24380.06872560642.92.1705474368
1x400/35CuRM0.2640.60.047883168057.22.1750505347
1x500/35CuRM0.2943.80.037895376571.42.4795536472